Ecocomfort2

The ecocomfort2 component lets you control a Fantini Cosmi Aspirvelo Air Ecocomfort 2.0 Smart heat recovery ventilation unit over BLE from an ESP32.

The component has a hub that keeps the BLE connection to one unit, a Fan platform that controls the unit’s air flow mode and speed, sensor platforms that report what the unit measures, and number, switch and select platforms for the unit’s settings. One ESP32 can control several units, with one hub per unit.

# Example configuration entry
esp32_ble:
io_capability: none
auth_req_mode: sc_bond
max_key_size: 16
esp32_ble_tracker:
ble_client:
- mac_address: "AA:BB:CC:DD:EE:FF"
id: vmc_ble
ecocomfort2:
- id: vmc_hub
ble_client_id: vmc_ble
fan:
- platform: ecocomfort2
name: "Ventilation"

The unit only accepts an encrypted, bonded BLE connection. The ESP32 BLE component must be configured with these settings, and the configuration is rejected otherwise. io_capability: none is already the default, so it only matters that it is not changed:

  • io_capability: none
  • auth_req_mode: sc_bond
  • max_key_size: 16

The first time the ESP32 connects, put the unit in pairing mode (see the unit’s manual). The bond is stored on the ESP32 and is kept across reboots and OTA updates, so later connections need no pairing mode. If pairing does not finish within 10 seconds, the component disconnects and the BLE client tries again.

See the BLE Client page for how to find the MAC address of the unit.

ecocomfort2:
- id: vmc_hub
ble_client_id: vmc_ble
  • id (Optional, ID): Manually specify the ID used for code generation.
  • ble_client_id (Required, ID): The ID of the BLE Client connected to the unit.
  • update_interval (Optional, Time): How often the operating state and the measurements are read from the unit. Defaults to 30s.
  • time_id (Optional, ID): A Time component to set the unit’s clock from. The clock is written once the time is known after each connection, and again whenever the time source syncs.
fan:
- platform: ecocomfort2
name: "Ventilation"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • All other options from Fan.

The fan has speeds 1 to 4. The preset selects the air flow mode:

  • In: air flows in only.
  • Out: air flows out only.
  • In-Out: air flows in both directions.
  • Sensor: the unit sets the air flow direction from its sensors.
  • Auto: the unit controls the speed itself. Setting a speed while in Auto switches to Sensor.

Setting only a speed keeps the current preset. Turning the fan off keeps the preset and speed, so turning it on again resumes them.

The on/off state always comes from the unit after the first read back. The fan’s restore_mode only brings back the last preset and speed after a reboot; set it to NO_RESTORE to skip that. After each change, the state is read back from the unit about 300 ms later.

sensor:
- platform: ecocomfort2
temperature:
name: "Ventilation Temperature"
humidity:
name: "Ventilation Humidity"
voc:
name: "Ventilation VOC"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • temperature (Optional): The air temperature measured by the unit, in °C. All options from Sensor.
  • humidity (Optional): The relative humidity measured by the unit, in %. All options from Sensor.
  • voc (Optional): The volatile organic compounds reading of the unit, in ppb. All options from Sensor.
  • direction (Optional): The air flow direction byte from the unit’s status, passed through as the unit sends it; the component does not decode it. It shows the unit switching direction in the In-Out and Sensor presets. All options from Sensor.
binary_sensor:
- platform: ecocomfort2
connected:
name: "Ventilation Connected"
boost:
name: "Ventilation Boost"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • connected (Optional): On while the ESP32 is connected and paired to the unit. All options from Binary Sensor.
  • boost (Optional): On while the unit runs its boost mode. All options from Binary Sensor.
text_sensor:
- platform: ecocomfort2
version:
name: "Ventilation Firmware"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • version (Required): The firmware version of the unit, read once per connection. All options from Text Sensor.

The number, switch and select platforms change settings stored in the unit, the same ones as in the vendor app. The unit holds the settings: they are read from it on every update, so a change made in the app shows up too, and a change is read back from the unit right after it is sent. Each change only touches its own setting.

number:
- platform: ecocomfort2
humidity_threshold:
name: "Ventilation Humidity Threshold"
temperature_offset:
name: "Ventilation Temperature Offset"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • humidity_threshold (Optional): How strongly the unit reacts to humidity, from 0 (off) to 3. All options from Number.
  • luminosity_threshold (Optional): How strongly the unit reacts to light, from 0 (off) to 3. All options from Number.
  • voc_threshold (Optional): How strongly the unit reacts to volatile organic compounds, from 0 (off) to 3. All options from Number.
  • temperature_offset (Optional): A correction added to the unit’s temperature reading, from -5 to 5 °C in steps of 0.1. It stays in °C even when Home Assistant shows temperatures in °F. All options from Number.
  • humidity_offset (Optional): A correction added to the unit’s humidity reading, from -5 to 5 % in steps of 1. All options from Number.
switch:
- platform: ecocomfort2
humidity_advanced:
name: "Ventilation Humidity Advanced Control"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • humidity_advanced (Optional): Advanced control for humidity: as the reading approaches the threshold, the unit raises its speed by one level. It needs humidity_threshold above 0; turning it on while the threshold is 0 is refused with a warning in the log, and the switch stays off. All options from Switch.
  • voc_advanced (Optional): The same for volatile organic compounds, with voc_threshold. All options from Switch.

Setting a threshold to 0 also turns its advanced control off.

select:
- platform: ecocomfort2
season:
name: "Ventilation Season"
free_cooling:
name: "Ventilation Free Cooling"
  • ecocomfort2_id (Optional, ID): The ID of the ecocomfort2 hub. Only needed when more than one hub is configured.
  • season (Optional): The season the unit runs in, Winter or Summer. All options from Select.
  • free_cooling (Optional): Free cooling, which cools the home with outside air at night: Off, Low, Medium or High. The unit only runs free cooling in summer, so it shows Off in winter, and changing it in winter is refused with a warning in the log. The unit keeps the level and uses it again when the season returns to summer. All options from Select.

Add one BLE client, one hub and one fan for each unit. With more than one hub, every ecocomfort2 platform entry, sensors included, names its hub with ecocomfort2_id:

ble_client:
- mac_address: "AA:BB:CC:DD:EE:FF"
id: vmc1_ble
- mac_address: "11:22:33:44:55:66"
id: vmc2_ble
ecocomfort2:
- id: vmc1
ble_client_id: vmc1_ble
- id: vmc2
ble_client_id: vmc2_ble
fan:
- platform: ecocomfort2
name: "Ventilation 1"
ecocomfort2_id: vmc1
- platform: ecocomfort2
name: "Ventilation 2"
ecocomfort2_id: vmc2
sensor:
- platform: ecocomfort2
ecocomfort2_id: vmc1
temperature:
name: "Ventilation 1 Temperature"